5 Notable Methods to Mitigate Arc Flash Switchgear in Medium Voltage Equipment (MVE)

arc flash switchgear

A blackout on the arc flash switchgear can interpret a blackout on a massive part of this facility since an MVE is supplying potential power to the LV feeds. 

At the same time, all medium voltage protective devices are efficiently operated with relays that should be set with a maximized time delay to ensure optimal coordination with downstream feeders.

Additionally, the circuit breaker for medium voltage has a more incredible opening time for the content being added into the relay signalling time. It makes us fault with the recent opening time that is distinctively greater than the low voltage circuit breakers. 

However, facility owners must search for ideal methods available for the mitigation of arch flash.

Today we will discuss the best practices involved, such as the follows:

Best practices for mitigating arc flash switchgear

1. Fault Current Limiters for restricted current flow

Many of the best practices for mitigating arc flash switchgear in the workplace stem from a basic understanding of current flow and how fault current limiters can be used to protect against possible accidents. They use superconductors, mainly operating with varied impedance concerning the recent magnitude. It operates under low impedance under the stable conditions of the flow of current through the medium voltage switchgear.

The limiter will implement additional impedance into this system that will limit the entire fault current of the magnitude, although it is not the case. We will discuss the limiters to fault current with the best instances.

2. Maintenance Switches

Some switches are manually operated and activated through the person’s work before the maintenance activities are undertaken. They will allow the adjustments to the 50P component resulting in speedy clearance of the arcing fault once activated in Arc Flash Switchgear. Arc flash is one of the most hazardous electrical events and can cause immediate or long-term injury or even death. Swapgear is a component of a switchgear and is designed to contain an arc flash in the event there is faulted current. A maintenance switch is used to isolate devices and equipment in a specific electrical system so that it remains electrically hot during mains power interruptions and outages.

The Switchgear is entirely inactive under the general operating conditions on the other instance. It would allow the clearance of the arcing fault included under the scheduled maintenance, and these can preserve the coordination within the downstream feeders under normal working conditions.

3. Arc Resistance Switchgear

Arc flash is a hazard that can be deadly if not attended to properly. Arc flash switchgear has been used for years by electricians to reduce the amount of damage in case of an electrical arc ramp. By knowing the best practices when installing arc resistant switchgear you will remain safe while completing your tasks. There will be a serious buildup of pressure over time, resulting in a huge explosion within the arc flash switchgear in the course. It can prove fatal for the executive who is nearby. But, the arc resistance switchgear is designed to channel the flow of the pressurized arcing energy away from the adjacent equipment and the adjacent personnel.

It has a robust structure with the capability of enduring the pressure and discharging gases through the built-in exhaust supported by the vents of the medium voltage equipment.

4. Differential Protection

It is a mechanism that allows the clearance of the internal faults without any time delays intentionally, maintaining adequate coordination of protection with other safeguard devices. It is employed normally within the equipment, including the transformers and the generators, and the differential protection is only deployed for the internal faults. 

No tripping or clearance will occur for the fault outside the protective zone, especially in terms of the external faults.

5. Arc Flash Detection Relays

These protective relays are specific, acting on the intensified light that emits through the arc flash. The maximum intensity and rapid tripping time lead to instant fault clearance. 

Sensing is generally done through the photo-electric receptors, taking insufficient light. The signal is sent to its attached protective relays for the occurrences of the tripping function. The method is quite relatively new, so it has become a popular technique of mitigation.

Ending Notes

The arc flash switchgear has a robust design with a built-in mechanism for pressure relief to mitigate medium voltage equipment. Combining these would reduce or eliminate the chances of an explosion, therefore, saving equipment and preventing any injury or downtime. 